MF-CLD127S is an IR cut filter, also called a cold filter, designed to transmit visible light while reducing infrared radiation and heat load.
It uses dielectric multilayer vapor-deposition coating on polished glass and is intended for optical systems where heat reduction and visible-light clarity are important.
Related products: OCA / Cold Filter category | MCS62 OCA film | M3D49 OCA film
|
|
What MF-CLD127S is used forMF-CLD127S is used when visible light needs to pass through an optical system while infrared radiation and heat load should be reduced. A cold filter can help protect heat-sensitive optical parts such as polarizers, optical films and display-related components from excessive infrared exposure. Typical Applications
|
|
■ Transmits visible light while reducing infrared radiation ■ Dielectric multilayer vapor-deposition coating on glass ■ Optical white / polished glass helps reduce color bias and image distortion ■ Useful for reducing heat load to polarizers and other optical films ■ Suitable for projector optics, gel documentation and optical test assemblies ■ Currently out of stock; future supply is uncertain |
| Item Code | Size | Availability | Unit Price |
| MF-CLD127S | 127 x 127 mm | t = 2.5 mm Effective area: 120 x 120 mm |
Out of stock | $ 332 Reference price |
MF-CLD127S is suitable for optical systems where infrared radiation from the light source may increase temperature or degrade heat-sensitive optical parts. Actual performance depends on the light source, distance, filter position and thermal environment.
Specification of MF-CLD127S IR Cut Filter |
||
Size and Structure | ||
| Outer size | mm | 127 x 127 |
| Effective area | mm | 120 x 120 |
| Thickness | mm | 2.5 |
| Substrate | Polished / ground optical glass | |
| Coating | Dielectric multilayer vapor-deposition coating | |
Optical Function | ||
| Function | Visible-light transmission with infrared radiation reduction | |
| Application note | Used for reducing infrared heat load in optical paths; not intended to eliminate all heat | |
Thermal Control Test Example | ||
| Light source | 250 W halogen lamp | |
| Test distance | Light to polarizer distance fixed at 80 mm; cold filter placed between light and polarizer | |
| Room temperature | ℃ | 23 |
| Measurement note | Measured at the center of the polarizer every 60 seconds. Data are measured values, not guaranteed values. | |
|
|
See also: OCA / Cold Filter category | MCS62 OCA film | M3D49 OCA film