AR (anti-reflection) film
Roll Type E 1000mm width
|
MFAR --- Roll Type AR film / 1000mm Width film (Permanent adhesive type) |
1000mm width |
Roll type AR film - MFAR
For large size LCD protective case,
show windows, etc.
MFAR has 1000mm width and
Available from minimum of 2 meters. |
|
|
 |
1000mm width
t = 0.1mm + Release layer 0.25mm |
Item Code |
Size |
Unit Price |
MFAR-Roll
(1000mm width) |
2 - 4 meter |
$182 / meter |
5 - 9 meter |
$169 / meter |
10 - 29 meter |
$153 / meter |
30 - meter |
$138 / meter |
A4 size (25 x 30cm) sample |
$28 |
Apply AR film on both sides for full effect.
Light reflects both on the front and the reverse side of glass surface.
Reflections are approx 4-5% for each side, and total reflection sum up
to approx 10%.
AR film reduces reflection down to approx 0.5% on each side and therefore
applying film on both side
would reduce total reflection down to less than 1% (1/10).
** Applying on only one side leaves out 5.5% reflection. Therefore please
apply on both side. |
|
Front
reflect |
|
Back
reflect |
|
Total
reflect |
without AR film |
5.0 % |
+ |
5.0 % |
= |
10.0 % |
AR film on one side |
0.5 % |
+ |
5.0 % |
= |
5.5 % |
AR film on both side |
0.5 % |
+ |
0.5 % |
= |
1.0 % |
|
Notice : Multi-layered glass such as
double/ triple glazing glass requires
film to be applied on every surface.
For instances, double glazing glass requires
film to be applied on all 4 surfaces. |
Specification & Inspection Criteria |
Optical Characteristic |
flectance curves |

*graph is actual measurement data |
|
Light transmission |
92% |
measuring
method |
Measured regular reflection at 5
using a spectrophotometer.
Coat with black paint after polishing
back of the sample with sandpaper. |
|
Haze |
0.75% |
Reflectance minimum |
less than 0.35% |
Reflectance minimum wavelength |
550nm |
Average spectral luminous efficacy reflectance rate |
0.6% |
|
Membrane characteristic |
Steel-wool abrasion |
good |
Measured with rubbing No.0000 steel-wool
back and forth 10 time with 250g/cu weight rub |
Pencil strength |
2H |
Compliance to JIS K540-1900 |
Adherence |
100/100 |
Cross-cut test |
Contact angle |
90 |
Genuine contact angle
Measured with CA-W150 (Kyowa Interface Science) |
finger print removability |
|
|
*Above is actual measurement data, not guaranteed data.
|
|